Key Verification Checks
- Configure /etc/multipath.conf vendor settings before attaching iSCSI/FC LUNs
- Use NFS v4.1/4.2 when qcow2 VM snapshots and thin provisioning are required
- Keep shared LVM-over-iSCSI constraints clear (thick LVM without native PVE snapshots)
- Test live migration speed and path failover by unplugging one storage uplink
1. Keeping Existing SAN Capital Productive
One of the biggest financial wins when moving off VMware is reusing existing Dell PowerStore, HPE MSA, NetApp, or Synology arrays. Connecting shared storage to Proxmox VE unlocks live VM migration across hosts and automated HA restarts without buying a hyperconverged Ceph cluster.
2. NFS vs. iSCSI/FC: Snapshot & Thin-Provisioning Trade-Offs
A key architectural difference surprises many VMware admins: on NFS shares, VM disks sit as .qcow2 files so native Proxmox snapshots and thin provisioning work seamlessly. On shared iSCSI or Fibre Channel LUNs formatted with classic Shared LVM, multiple hosts access the same raw block device, meaning Proxmox cannot use thin-LVM or qcow2 snapshots directly (only thick LVM volumes or hardware SAN-level snapshots apply).
| Protocol | PVE Snapshots | Thin Provisioning | Operational Notes |
|---|---|---|---|
| NFS v4.1 / v4.2 | Yes (qcow2) | Yes | Ensure dual-controller NAS/HA redundancy |
| iSCSI / FC + Shared LVM | No (Thick LVM) | No (classic LVM) | Requires properly tuned multipath.conf |
| ZFS over iSCSI | Yes | Yes | Requires supported TrueNAS / Linux iSCSI target |
3. Multipath (MPIO) Verification for iSCSI & FC
Dual-controller SANs connected across redundant storage switches must run multipath-tools with vendor-specific ALUA and path_grouping_policy rules inside /etc/multipath.conf. Always test an active link pull during commissioning so one failed switch never locks VM disks read-only.
# Install and inspect active redundant MPIO paths
apt install -y multipath-tools
multipath -ll
# Verify NFS protocol version and mount options
nfsstat -mInteractive Tool · Storage & Memory Sizing
Size ZFS ARC RAM Caps & Usable Ceph Capacity
Pick your node count and raw NVMe/SSD capacity to calculate safe ZFS ARC memory limits and net usable Ceph storage before provisioning. HA / DR Architecture →
Frequently Asked Technical Questions
Proxmox Backup Server (PBS) and vzdump capture live backups cleanly at the QEMU block layer—scheduled daily incremental backups work even without storage-level snapshots.
Hands-On Engineering & Consulting
Let’s review this topic against your live cluster
Share your host and VM count; we will define the safest scope in a free 15-minute discovery call.